W02 Vin overvoltage error in JFY solar inverter

You are here:
Estimated reading time: 1 min

W02 Vin overvoltage error in JFY solar inverter

Solution

Check the Voc of PV string, see if it is greater than or too close to max. Input DC voltage of relative inverter type.

 

NOTE: During periods of little or no sunlight, the solar inverter may continuously start up and shut down. This is due to insufficient power generated to operate the control circuits, not trouble.

 

If you can not solve the trouble with the above procedures, Please contact Solarmatic or service personnel.

Before contacting the Solarmatic or service personnel, please find and keep at hand the following information:

Information of JSI inverter

  1. Inverter Model
  2. Serial Number
  3. Week of manufacture
  4. Which LED is red?
  5. Which warning/error is displayed?
  6. Do you notice whether warning/error can be repeated?

Information on the PV array

  1. The model and manufacturer of the PV panels
  2. Number of strings in the PV array and number of panels per string