Fronius Primo 3.0-1 / 3.5-1 / 3.6-1 / 4.0-1 4.6-1 / 5.0-1 AUS / 5.0-1 5.0-1 SC / 6.0-1 / 8.2-1 Class 3 Error Code

You are here:
Estimated reading time: 1 min

Fronius Class 3 State Error Codes

Fronius Class 3 State errors – Class 3 includes status codes that may occur while feeding energy into the grid, but generally do not cause the process to be interrupted for any length of time. The inverter disconnects automatically from the grid, the grid is then monitored as specified and the inverter attempts to resume feeding energy into the grid.

Code

Description

Behavior

Remedy

STATE 301 Overcurrent (AC) Short-term interruption while feeding energy into the grid due to overcurrent in the inverter.
The inverter resumes with its startup routine.
The fault is rectified automatically; if this STATE code is displayed all the time: notify your local Fronius service partner.
STATE 302 Overcurrent (DC)
STATE 303 The power stage set over temperature Short term interruption while feeding energy into the grid due to over temperature.
The inverter resumes with its startup routine.
Purge openings for cooling air and heat sink if necessary; the fault is rectified automatically; if this STATE code keeps recurring contact your solar power system installer.
STATE 304 Internal temperature too high
STATE 306 LOW PV OUTPUT
Intermediate circuit voltage too low for feeding energy into the grid
Short term interruption while feeding energy into the grid.
The inverter resumes with its startup routine.
The fault is rectified automatically; if this STATE code occurs when there is sufficient insolation (sunlight) contact your solar power system installer.
IMPORTANT! Due to the low level of insolation (sunlight) early in the morning and in the evening, the STATE codes 306 (LOW PV OUTPUT) and 307 LOW PV VOLTAGE) are displayed routinely at these times of the day. These STATE codes do not indicate any kind of fault.
STATE 307 LOW PV VOLTAGE
DC input voltage too low for feeding energy into the grid
STATE 308 Intermediate circuit overvoltage Short term interruption while feeding energy into the grid. The inverter resumes with its startup routine. The fault is rectified automatically; if this STATE code is displayed all the time: notify your local Fronius service partner.
STATE 309 DC input voltage MPPT 1 too high
STATE 313 DC input voltage MPPT 2 too high
Was this article helpful?
Dislike 0 0 of 0 found this article helpful.
Views: 1517

Continue reading

Previous: Fronius Primo 3.0-1 / 3.5-1 / 3.6-1 / 4.0-1 4.6-1 / 5.0-1 AUS / 5.0-1 5.0-1 SC / 6.0-1 / 8.2-1 Class 4 Error Code
Next: Fronius Primo 3.0-1 / 3.5-1 / 3.6-1 / 4.0-1 4.6-1 / 5.0-1 AUS / 5.0-1 5.0-1 SC / 6.0-1 / 8.2-1 Class 1 Error Code
0 replies

Leave a Reply

Want to join the discussion?
Feel free to contribute!

Leave a Reply

Your email address will not be published. Required fields are marked *

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

We offer maintenance service in NSW region only!

Call us now on 1300 980 640
Click here to email us
SYDNEY’S LEADING SUPPLIER OF RESIDENTIAL AND COMMERCIAL SOLAR SYSTEMS.
close-link
Know More