The following is a list of ABB inverter error codes, messages, causes and solutions from ABB Aurora Power-One Inverter user manual. The following list contains the error and alarm messages that the ABB Aurora Power-One inverters may display along with the procedures for solving possible problems and some appropriate troubleshooting tips. If you require any further assistance please call us on 1300 980 640.
Message |
Warning |
Error
|
Description |
---|---|---|---|
Sun Low | W001 | Input Voltage under the threshold Input voltage under the threshold (when off) |
|
Input OC | E001 | Input Over-current | |
Input UV | W002 | Input Under-voltage | |
Input OV | E002 | Input Over-voltage | |
Int. Error | E003 | No parameters | |
Bulk OV | E004 | Bulk Over-voltage | |
Int. Error | E005 | Communication Error | |
Out OC | E006 | Output Over-current | |
Int. Error | E007 | IGBT Sat | |
Sun Low | W011 | Bulk Under-voltage | |
Int. Error | E009 | Internal Error | |
Grid Fail | W003 | Grid Fail Wrong grid parameters |
|
Int. Error | E010 | Bulk Low | |
Int. Error | E011 | Ramp Fail | |
DC/DC Fail | E012 | DcDc Error revealed by inverter DcDc fault detected by inverter |
|
Wrong Mode | E013 | Wrong Input setting (Singe instead of dual) Wrong Input setting (Single instead of dual-channel) |
|
Over Temp. | E014 | Over-temperature Internal temperature too high |
|
Cap. Fault | E015 | Bulk Capacitor Fail Bulk capacitor fault |
|
Inv. Fault | E016 | Inverter fail revealed by DcDc Inverter fault detected by DcDc |
|
Int. Error | E017 | Start Timeout | |
Ground F. | E018 | I leak fail Leakage current fault |
|
Int. Error | E019 | I leak Sensor fail Leakage current fault |
|
Int. Error | E020 | DcDc relay fail DcDc relay fault |
|
Int. Error | E021 | Inverter relay fail Inverter relay fault |
|
Int. Error | E022 | Autotest Timeout | |
Int. Error | E023 | Dc-Injection Error | |
Grid OV | W004 | Output Over-voltage | |
Grid UV | W005 | Output Under-voltage | |
Grid OF | W006 | Output Over-frequency | |
Grid UF | W007 | Output Under-frequency | |
Z Grid HI | W008 | Z grid out of range Impedance outside range |
|
Int. Error | E024 | Unknown Error – Internal Error |
|
————- | E025 | Riso Low (Log Only) Low insulation resistance (Log only) |
|
Int. Error | E026 | Vref Error Wrong reference voltage (VRef) |
|
Int. Error | E027 | Vgrid Measures Fault Grid voltage (VGrid) misreading |
|
Int. Error | E028 | Fgrid Measures Fault Grid frequency (FGrid) misreading |
|
Int. Error | E029 | Zgrid Measures Fault | |
Int. Error | E030 | Ileak Measures Fault Leak current (ILeak) misreading |
|
Int. Error | E031 | Wrong V Measure Voltage (V) misreading |
|
Int. Error | E032 | Wrong I Measure Current (I) misreading |
|
Fan Fail | W010 | Fan Fail (no disconnection) Fan Faulty (Log Only) |
|
Int. Error | E033 | Under Temperature Internal Temperature |
|
E034 | Interlock Fail (Not Used) | ||
E035 | Remote Off Remote power-off |
||
E036 | Vout Avg Average output voltage outside range |
||
W012 | Clock Battery Low (No disconnection) Clock battery low (not operating) |
||
W013 | Clock Failure (No disconnection) Clock faulty (not operating) |